Expert repairs for all Vaillant boiler models. Our qualified engineers diagnose and fix faults quickly to restore your heating and hot water.

5 out of 5 stars
I had an issue with my boiler not giving hot water properly, very odd shuddering sounds and infrequent clicking noises. Dan came out as an emergency the same day and sorted the issue out! Would recommend
When something's wrong, a Vaillant ecoTEC or ecoFIT shows a code starting with F on its display. Here's what the common ones mean, what you can safely check yourself, and when it needs an engineer. The meanings come from Vaillant's own fault code guide.
Never take the casing off your boiler. If you smell gas, call the National Gas Emergency Service on 0800 111 999 straight away.
The flow temperature sensor has been interrupted. An electrical fault or a faulty sensor.
Needs an engineer.
The return temperature sensor has been interrupted. An electrical fault or a faulty sensor.
Needs an engineer.
The flow temperature sensor has short-circuited. An electrical fault or a faulty sensor.
Needs an engineer.
The return temperature sensor has short-circuited. An electrical fault or a faulty sensor.
Needs an engineer.
The hot water temperature sensor has short-circuited. An electrical fault or a faulty sensor.
Needs an engineer.
The cylinder temperature sensor has short-circuited. An electrical fault or a faulty sensor.
Needs an engineer.
The safety thermal cut-out has switched the boiler off because it got too hot. Often low pressure or poor circulation.
You can check: Check the pressure gauge, look for leaks, make sure radiator valves are open and bleed any radiators that are cold at the top.
Low water pressure in the heating system.
You can check: If the gauge reads below 1 bar, top it up to between 1 and 1.5 bar with the filling loop. If it keeps dropping, there's a leak or a faulty expansion vessel.
The temperature difference between flow and return is too great. Usually air in the boiler or poor circulation.
You can check: Check the pressure gauge and bleed any radiators that are cold at the top.
The temperature is rising too quickly. Usually air, low pressure or poor circulation.
You can check: Check the pressure gauge and bleed any radiators that are cold at the top.
The flue gas temperature is too high.
Needs an engineer.
A flame signal was detected while the burner was off. A safety lockout, often the gas valve or circuit board.
Needs an engineer.
The boiler tried to light but no flame was detected. Common causes are no gas, an empty prepayment meter or a frozen condensate pipe.
You can check: Check your other gas appliances work and your prepayment meter has credit. In freezing weather, thaw the condensate pipe with warm (not boiling) water, then reset the boiler once.
The flame went out and the boiler couldn't relight. Common causes are an interrupted gas supply or a frozen condensate pipe.
You can check: Check your other gas appliances work and your prepayment meter has credit. In freezing weather, thaw the condensate pipe with warm (not boiling) water, then reset the boiler once.
Fan fault.
Needs an engineer.
The air or flue pipe is blocked.
You can check: If it's safe to reach at ground level, check the flue outside isn't blocked and the condensate pipe isn't frozen.
Mass flow sensor fault.
Needs an engineer.
Combustion regulation fault, often low gas pressure.
You can check: Check your gas supply and prepayment credit, and that the condensate pipe isn't frozen.
Gas supply fault, usually shown with F.28 or F.29.
You can check: Check your gas supply and prepayment credit, and that the condensate pipe isn't frozen.
The boiler isn't burning correctly in comfort mode.
You can check: Check your gas supply and prepayment credit, and that the condensate pipe isn't frozen.
The flame took too long to go out after switch-off. Usually the gas valve, circuit board or ignition electrode.
Needs an engineer.
The boiler's device number is missing or wrong, usually after a part has been replaced.
Needs an engineer.
The flow and return sensors are giving readings that don't make sense.
Needs an engineer.
No pressure change was detected when the pump started. Low pressure, air in the system, or a faulty pump or pressure sensor.
You can check: If the gauge reads below 1 bar, top it up to between 1 and 1.5 bar with the filling loop and bleed the radiators.
Little or no temperature rise when the burner starts. Usually low pressure or poor circulation.
You can check: Check the pressure gauge and top it up if it's below 1 bar.
The flow and return temperature readings don't make sense, often crossed pipework or misplaced sensors.
Needs an engineer.
The electrical connection to the gas valve has been interrupted.
Needs an engineer.
Code not listed, or still there after your checks?
If it's over 10 years old or keeps breaking down, it may be time for a new one. New boilers are fitted at a fixed price, from £1,910.
Get a new boiler priceVaillant boilers are known for their quality and reliability, but even the best boilers can develop faults. Our specialist engineers have extensive experience with Vaillant systems and carry common parts to fix issues on the first visit.
Our engineers receive specific training on Vaillant boilers, ensuring they understand the intricacies of these premium German-engineered systems.
We use authentic Vaillant components to maintain your manufacturer's warranty and ensure optimal performance and longevity.
We thoroughly assess your Vaillant boiler using advanced diagnostic tools to identify the precise cause of any issues before recommending repairs.

When it's time for a new boiler, these are the Vaillant boilers we fit. Each price is fixed and includes fitting, for a like-for-like swap in the same place, with your old boiler taken away, a new flue, a magnetic filter, a system flush and a thermostat. Moving the boiler or switching type adds a fixed amount, shown before you book.
| Boiler | Hot water | Warranty | Fitted price |
|---|---|---|---|
| Vaillant ecoFIT pure 825 Combi boiler, 18kW heating | One shower or bath at a time | 10 years | £2,669 |
| Vaillant ecoFIT pure 830 Combi boiler, 25kW heating | Two showers or baths at once | 10 years | £2,700 |
| Vaillant ecoTEC plus 832 Combi boiler, 25.5kW heating | Two showers or baths at once | 10 years | £3,190 |
| Vaillant ecoTEC plus 836 Combi boiler, 29.9kW heating | Three showers or baths at once | 10 years | £3,490 |
| Vaillant ecoTEC plus 630 System System boiler, 30kW heating | From your hot water cylinder | 10 years | £2,999 |
| Vaillant ecoTEC plus 424 Regular Regular boiler, 24kW heating | From your hot water cylinder | 10 years | £2,899 |
Common Vaillant boiler issues include pressure loss, ignition failures, pump problems, diverter valve faults, and error codes like F.22, F.28, or F.75. Our engineers are familiar with all Vaillant fault codes and can quickly diagnose and resolve these issues.
We aim to repair your Vaillant boiler on the first visit whenever possible. For standard appointments, we can typically attend within 24-48 hours. If parts need to be ordered, we'll provide a clear timeframe for the repair completion.
No, our repairs won't void your warranty as we use genuine Vaillant parts and follow manufacturer guidelines. If your boiler is still under warranty, we can advise whether the repair might be covered by Vaillant directly.
With proper maintenance, Vaillant boilers typically last 10-15 years. Regular servicing can extend their lifespan and maintain efficiency. If your Vaillant boiler is approaching this age, we can advise whether repair or replacement offers better value.
This depends on the boiler's age, condition, and the nature of the fault. For Vaillant boilers under 10 years old, repairs are usually worthwhile. For older models with significant issues, we'll provide honest advice about whether repairing or replacing your Vaillant boiler offers better long-term value.
£120 fixed price, following Vaillant's warranty guidelines.
A quick test for boilers that keep breaking down.
Every boiler we fit, with its fitted price.
New boilers fitted by our own London team, at a fixed price.